Air Transat 236

Printed page 82. PDF page 82.

103 Released copy 2.7.2.2 Chemical Oxygen Generator R3 Installation The presence of a maintenance installation retaining pin in the oxygen generator at flight atten- dant position R3, and the fact that this installation had not activated since the aircraft was
Open official document at PDF page 82All Engines-out Landing Due to Fuel Exhaustion: Air Transat A330 C-GITS

Air Transat 236

Printed page 86. PDF page 86.

oxygen masks to not be available for use by the passengers. 6. The failure to remove the maintenance installation retaining pin from the oxygen regulator at position R3 resulted in the contained masks to be unavailable for use by the
Open official document at PDF page 86All Engines-out Landing Due to Fuel Exhaustion: Air Transat A330 C-GITS